JET™ / Jacketed External Telemetry Blood Pressure

The JET Blood Pressure Add-On
Expand on your Jacketed External Telemetry (JET™) capabilities with
the JET BP Add-On and acquire accurate, continuous blood pressure
data from a minimally invasive implant. No other system provides
comparable accuracy or power for hemodynamics studies.
JET BP Add-On
The JET Blood Pressure Add-On consists of a remote antenna receiver
and electronics module that are interfaced directly to the JET device.
Together these components receive a signal from a DSI pressure-only
implant. The implant and receiver antenna should be as close as
possible for optimal performance.
Implant
The DSI pressure-only implant is typically placed in the femoral or
carotid artery to enable a direct blood pressure measurement via a
simple, fast, and minimally invasive surgical procedure with a rapid
recovery. Based on experience with canines and primates, the duration
is 10 – 15 minutes from first incision to final suture. Implant sites are
typically located within the optimal distance of a JET BP antenna that is
housed inside a protective jacket.
Accurate and Continuous Data and Analysis
Accurate, continuous blood
pressure data allows for
determination of Systolic,
Diastolic, and Mean
pressures, along with Heart
Rate and +/-dP/dt on a
beat-to-beat basis – and you
can look at the waveform
morphology!

Histopathology
Due to the small size and
simple surgery, histopathology
concerns can be successfully mitigated. No significant histopathology
was observed following implantation of up to 15 weeks. |
DSI Pressure Only Implants
PA-C10-TOX-SA/PA-C10-TOX-LA
- Specially designed for large animal JET studies
- 1.1 cc plus suture rib and catheter
- SA Catheter: ~0.7 mm diameter with 7, 8, or 10 cm length
- LA Catheter: ~1.2 mm diameter with 10, 15, or 25 cm length
- 6 week continuous battery life
Note: The standard PA-C10 is not recommended for this application
PA-C40
- 4.5 cc
- 8, 10, or 15 cm catheter length
- 4 month continuous battery life
PA-D70
- 25 cc
- 25, 30, 35, or 40 cm catheter length
- 4 month continuous battery life
|
Obtaining Blood Pressure via JET requires a minimally invasive implant; however, researchers seeking highly accurate and continuous blood pressure waveform data, will find other technologies just do not compare.
Non-Invasive Blood Pressure Cuff
- Significantly less accurate
- Non-continuous
- Stress inducing
- Typically non-ambulatory
- Difficult to use in ambulatory implementations
Catheter via Vascular Access Port
- Potential for infection
- Requires significant maintenance
- Use of heparin in port maintenance produces complications
- Surgical procedure required
Pulse Transit Time
- Indirect measure relying on multiple assumptions and complex calculations that although theoretically accurate have not been proven in practice
- Non-continuous
- Difficult to use in ambulatory implementations
High Density Oscillometry
- Difficult to use in ambulatory implementations
- Typically non-ambulatory
|
Crosstalk is possible when using JET Blood Pressure in
a group-housing situation. However, the design of the
system minimizes the possibility of crosstalk because
the PA-C10-TOX implant has a short transmission range
and the JET BP Antenna may be placed very close to
the implant. |
|