7700 Series Isolated/Defibrillation Protected ECG and General Purpose Probes

7700 Series Isolated/Defibrillation Protected ECG and General Purpose ProbesFeatures
  • 3 Lead connection with an array of electrodes
  • Provides galvanic isolation to the signal conditioner
  • Protects signal conditioner from defibrillator discharges
  • Built-in “Zero” and “Cal” buttons for ease in calibrating channel

The Isolated Defibrillation Protected ECG and General Purpose Probes (13-7758-IDP and 13-7758-GPP) are designed to conduct pre-clinical studies and investigation (clinical research) of physiological processes.  The probes are suitable for intra cardiac, surface electrodes, Action Potential measurements or other applications where isolation is needed.  Additionally, built-in Zero and Cal buttons provide for a simple, accurate calibration process.  The probes interface  specifically to the 7700 Series Universal Signal Conditioner, model 13-7715-58.

Technical Data Sheet
Model 13-7758-IDP and 13-7758-GPP
Isolated/Defibrillation Protected Probes
SPECIFICATIONS

Electrical Specifications
Gain                                                       x10
Maximum Output Range                    ±2.5VDC
Input Leads                                           RA, LA, RL (+, -, REF)
Dynamic Range                                   ±250mV
Maximum input DC offset                                 ±300mV
Input Impedance                                 50MΩ @ 10Hz when using fully shielded cable (ConMed FSR 397 with patient cable and lead wires).
CMRR                                                    -90dB @ 60Hz with 51kΩ, 0.047uF source imbalance
Input Risk Current                                < 10μA @ 265V RMS 60Hz, sink all leads to ground
Defibrillator Protection                       360Joules delivered at 5000Volts
Isolation                                                 1500V RMS for 1 minute,   isolated circuits to chassis
Noise                                                     <30μV p/p @ 1kHz
Bandwidth                                             0.05 to 3.5kHz
Calibration                                            1mV (ECG), 50 mV (GPP)

Physical Specifications
Height                                                    1.2 inches
Width                                                      3.2 inches
Length                                                   5.9 inches
Weight                                                   0.5 pounds

Environmental Specifications
Temperature
Operating                                              0 to 40° C  
Storage                                                  20 to 70° C

Humidity RH, non-condensing
Operating                                              10% to 95%
Storage                                                  5% to 95%
Cooling                                                  Convection only
Altitude                                                  2000 meters maximum

ORDERING INFORMATION

Part Number        Description
13-7758-IDP           ACQ-7700 Universal Signal Conditioner

Accessories
P02141                   ECG Cable Kit (Contains the following 5       
                                  items)
P02143-2               Grabber Lead Wire, set of 3
P02143-3               Banana Lead Wire, set of 3
P02143-4               Banana to CLIP Adapter, 3 each
P02143-5               0.80 Receptacle Lead Wire, set of 3

Safety
EN 60601-1: 1990, Medical Electrical Equipment, Part 1
        General Requirements for Safety  Including Amendments 1 and 2: 1995
EN 60601-2-25: 1993, Medical Electrical Equipment, Part 2
        Particular requirements for the safety of electrocardiographs. Except for clause 51.103 Indication of          inoperable ELECTROCARDIOGRAPH.

Emissions
EN 55011: 1991, Conducted and Radiated Emissions, Class A
EN 61000-3-2: 1995, Harmonics, Class A
EN 61000-3-3: 1995, Flicker

Immunity
EN 61000-6-2 and EN 60601-1-2
EN 61000-4-2: 1995, Electrostatic Discharge, 2,4,8 kV
EN 61000-4-3: 1998, Radiated EM field, AM modulation, 10 V/m
ENV 50204: 1995 Radiated EM Field, Pulse modulation,10 V/m
EN 61000-4-4: 1995, Fast Transient / Burst, 1,2 kV
EN 61000-4-5: 1995, Surge Immunity 0.5, 1, 2 kV
EN 61000-4-6: 1996, Conducted RF Disturbances, 10 V/rms
EN 61000-4-11: 1994, Voltage Dips, 95%/10ms, 70%/.1s, 40%/.5s, 95%/5s